Backflow prevention

Overview
Water systems depend on water pressure to keep water flowing in the proper direction through the pipes.  However, a sudden or unexpected change in water pressure can cause an undesirable reversal in the normal flow of water.  This is called backflow.  During a backflow event, water runs backwards from the consumer’s water system and returns to the public water distribution system.  The reversal of flow can allow potentially contaminated water to flow back into the public water supply, creating a possible health risk.  For example, soapy water or other cleaning compounds can backflow through a hose submerged in a laundry basin or lawn chemicals can backflow through submerged irrigation nozzles.
 Image Credit: North Wales Water Authority, website

Backflow is caused by two hydraulic principals: back siphonage and back pressure.  Both occur when a pressure differential exists in the piping system causing lower pressure in the public water distribution system and a higher pressure in the consumer’s water system.  Back siphonage occurs when there is unusual drop in pressure within the public water distribution system due to extreme water demand such as a water main break, hydrant flushing or fighting a fire.  Back pressure occurs when there is an increase in pressure within the consumer’s water system due to elevation or mechanical pumping above the pressure of the public water distribution system.  In both cases, water will flow from the high pressure system to the low pressure system; potentially allowing drinking water to become contaminated and unusable within the public water distribution system.

 Image Credit: Joint Municipal Water and Sewer Commission, website



 

cross connections
Cross connections are locations within the piping system where possible backflow can occur if a pressure differential exists.  It is a point in the water system where a contaminant or non-potable water from the consumer’s water system can potentially enter the public water supply.  Common cross connections for residential properties include lawn irrigation systems, garden hose connections to chemical solution aspirators (to fertilize lawn and shrubs), hose bibs, swimming pools and private wells.  Common cross connections for commercial properties include fire sprinklers, boilers, chillers, chemical mixing tanks, pressure pumps as well as lawn irrigation systems.

  Image Credit: City of Kent, Washington, website

 

Backflow prevention devices
A backflow prevention device is mechanical assembly installed in the water line to prevent backflow from occurring at cross connections.  This device will prevent potentially contaminated water from the consumer’s water system from flowing backward into the public water system.  It ensures that a one-way system is maintained.  Backflow prevention devices are installed between the consumer’s water meter and the first branch line in their private plumbing.  For commercial properties, this is typically located at the curb box (where the private water line connects to the City’s water main).  For residential properties, this is typically located immediately after the water meter along the outside of the home.
 Image Credit: District of Columbia Water and Sewer Authority, website
 
 
Image Credit: Global Water Resources, website


BACKFLOW PREVENTION PROGRAM
The Ohio EPA requires the maintenance of a continuing backflow prevention program that will systematically and effectively prevent the contamination of all potable water systems.  The purpose of Gahanna’s backflow prevention program three-fold: 1) to protect the public potable water supply from contamination or pollution by isolating within the consumer’s water system contaminants or pollutants which could backflow through the service connection into the public potable water system, 2) to promote the elimination or control of existing cross connections, actual or potential, between the public or consumer’s potable water system and nonpotable water systems, plumbing fixtures and sources or systems containing process fluids and 3) to provide for the maintenance of continuing a program of cross connection control which will systematically and effectively prevent the contamination or pollution of the public and consumer’s potable water systems.

The City’s backflow prevention program monitors the status of containment principle backflow prevention devices only.  Isolation principle backflow prevention devices are monitored by Franklin County Public Health, FCPH, not the City.  The City requires property owners to have each containment principle backflow prevention device on the property tested once every twelve (12) months by an Ohio Department of Commerce certified backflow tester to ensure that each is working properly.  Furthermore, the property owner is responsible for maintaining a complete record of each backflow prevention device from purchase to retirement.  This includes a record of all tests, inspections, repairs and overhauls.  The City prohibits any device from being bypassed, made inoperative, removed or otherwise made ineffective without specific authorization of the Water Resources Engineer.

Download: Backflow Prevention Test Report